Sign In | Join Free | My chinacomputerparts.com
China Tonglu Wanhe Medical Instrument Co., Ltd. logo
Tonglu Wanhe Medical Instrument Co., Ltd.
For the better life!
Verified Supplier

2 Years

Home > Laparoscopic Surgical Instruments >

ISO13485 Certified Steel Laparoscope Instruments Titanium Clip Applicator for Medical

Tonglu Wanhe Medical Instrument Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

ISO13485 Certified Steel Laparoscope Instruments Titanium Clip Applicator for Medical

Model NO. : HF2001.1

Size : Phi 10*330mm

Specifications : Single Action, for Flat-Middle Clip

OEM : Acceptable

ODM : Acceptable

Transport Package : Standard Export Packing

Specification : Steel

Trademark : Vanhur

Origin : Tonglu, Zhejiang, China

HS Code : 9018909919

Supply Ability : 500 PCS/Month

Type : Clip Applier

Application : Abdominal

Material : Steel

Feature : Reusable

Certification : CE, FDA, ISO13485

Group : Adult

Customization : Available | Customized Request

Contact Now

1 Introduction:
The titanium ligating applier is always used with titanium clips in endoscopic for ligating tissue and vessel. We provide three standard colour coding for easy identification. And we also can manufacture the type what you want.

2 Specifications
a. Adopt high quality stainless steel material.
b. Corrosion resistant
c. Tough construction
d. Large, lightweight rotation knob allows one-finger, 360° rotattion of applier shaft.
e. Flush ports for thorough cleaning

Model Name Specifications
HF2001.1 Titanium clip applier, for flat-middle clip, single action Φ10×330mm
HF2001.1B Titanium clip applier, for large clip, single action Φ10×330mm
HF2001.2 Titanium clip applier, for flat-middle clip, dual action Φ10×330mm
HF2001.3 Titanium clip applier, for flat-middle clip, side-loaded Φ10×330mm
HF2001.4 Titanium clip applier, for small clip Φ5×330mm
HF2001.5 Titanium clip applier, for flat middle clip, distal head disassembly Φ10×330mm

3 Packing & Shipping:
Package detail: Poly bag and special shockproof paper box.
Delivery detail: By air
ISO13485 Certified Steel Laparoscope Instruments Titanium Clip Applicator for Medical
ISO13485 Certified Steel Laparoscope Instruments Titanium Clip Applicator for MedicalISO13485 Certified Steel Laparoscope Instruments Titanium Clip Applicator for MedicalISO13485 Certified Steel Laparoscope Instruments Titanium Clip Applicator for MedicalISO13485 Certified Steel Laparoscope Instruments Titanium Clip Applicator for MedicalISO13485 Certified Steel Laparoscope Instruments Titanium Clip Applicator for Medical


FAQ


How to perform tissue cutting and coagulation in laparoscopic surgery?

In laparoscopic surgery, tissue cutting and coagulation is a delicate and technically demanding process, which usually involves the use of advanced electrosurgical instruments. Here are some key steps and technical points of this process:

Correct use of electrosurgical instruments: Electrosurgical instruments, such as electrocoagulation hooks, electrocoagulation forceps or ultrasonic scalpels, are commonly used tools in laparoscopic surgery. They can simultaneously achieve tissue cutting and coagulation and reduce bleeding. In order to protect the function of important organs such as the ovaries, it is particularly important to select electrosurgical instruments with less thermal damage to ensure that the damage to surrounding tissues during cutting is minimized. The range of damage is usually controlled to about 3mm.

Pre-separation technology: Before direct electrocoagulation or cutting, mechanical separation or hydrodissection is usually used to define the cutting line, which helps to reduce accidental damage to healthy tissues. Especially for adhesion tissues, such as adhesions of fallopian tubes and ovaries, separation is performed first to restore their normal function.

Combination of sharp and blunt separation: Sharp separation uses scissors, electric scalpels, etc. for precise cutting, while blunt separation uses instruments such as grasping forceps to push away tissue. The combination of the two can expose the surgical area more safely and reduce damage.

Precise hemostasis: It is very important to perform precise hemostasis immediately at the same time or after cutting. Electrocoagulation instruments can be used to seal small blood vessels and reduce bleeding. The operator needs to judge when and where to apply electrocoagulation based on the color, texture and amount of bleeding of the tissue to avoid tissue damage caused by excessive electrocoagulation.

Energy setting adjustment: The energy output of the electrosurgical device should be appropriately adjusted according to the surgical site and tissue type to achieve the best cutting effect and minimize secondary damage. Low energy settings are used for more delicate operations, and high energy is used for rapid cutting or processing of larger blood vessels.

Continuous monitoring: During the operation, the doctor will continuously monitor the tissue response and electrosurgical effect to ensure that the operation is safe and effective.

Tissue protection measures: For delicate or sensitive tissues, such as the ovaries, special protective measures may be taken, such as the use of specific protective pads or barriers, and the use of low-temperature or low-power electrocoagulation modes to reduce potential damage to ovarian function.

Through these techniques and steps, tissue cutting and coagulation during laparoscopic surgery are completed efficiently and safely, while maximizing the protection of the patient's health and organ function.

For more photos and details please contact me:
Company Name: Tonglu Wanhe Medical Instruments Co., Ltd.
Sales: Aiden



Product Tags:

iso13485 laparoscopic surgery instruments

      

iso13485 laparoscopic surgical instruments

      

steel laparoscopic surgery instruments

      
China ISO13485 Certified Steel Laparoscope Instruments Titanium Clip Applicator for Medical factory

ISO13485 Certified Steel Laparoscope Instruments Titanium Clip Applicator for Medical Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Tonglu Wanhe Medical Instrument Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)